Indoor Fiber Optic Cable
Micromodule Cable
Micromodule Integrated Optical Fiber Cable
High-density indoor cable made of hand-strippable micromodules.

Overview
What this cable is built for.
Each micromodule holds 1 to 24 fibers in a thin sheath that can be stripped by hand. Several micromodules stranded together form the integrated cable, which is small and dense for its fiber count.
Key features
- Hand-strippable micromodules
- 1 to 24 fibers per module
- High density, small diameter
- Supports mid-span access
Applications
- Indoor integrated wiring
- High-density buildings
Specifications
Technical specifications.
| 6 | Cable diameter 1.15±0.05 ± 0.004 in (0.1 mm); Cable weight 1 lb / kft (1.4 kg / km); Minimum bending radius static 1.18 in (30 mm); Minimum bending radius dynamic 2.36 in (60 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 8 | Cable diameter 1.5±0.06 ± 0.004 in (0.1 mm); Cable weight 1 lb / kft (2.1 kg / km); Minimum bending radius static 1.18 in (30 mm); Minimum bending radius dynamic 2.36 in (60 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 12 | Cable diameter 1.5±0.06 ± 0.004 in (0.1 mm); Cable weight 1 lb / kft (2.2 kg / km); Minimum bending radius static 1.18 in (30 mm); Minimum bending radius dynamic 2.36 in (60 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 48 | Cable diameter 7.6±0.30 ± 0.02 in (0.5 mm); Cable weight 34 lb / kft (50.5 kg / km); Minimum bending radius static 2.99 in (76 mm); Minimum bending radius dynamic 5.98 in (152 mm); Tensile load Short term 450 lbf (2000 N); Tensile load Long term 202 lbf (900 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 144 | Cable diameter 10.0±0.39 ± 0.02 in (0.5 mm); Cable weight 51 lb / kft (75.6 kg / km); Minimum bending radius static 3.94 in (100 mm); Minimum bending radius dynamic 7.87 in (200 mm); Tensile load Short term 450 lbf (2000 N); Tensile load Long term 202 lbf (900 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 288 | Cable diameter 13.0±0.51 ± 0.02 in (0.5 mm); Cable weight 91 lb / kft (135.2 kg / km); Minimum bending radius static 5.12 in (130 mm); Minimum bending radius dynamic 10.24 in (260 mm); Tensile load Short term 450 lbf (2000 N); Tensile load Long term 202 lbf (900 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
Ready to order Micromodule Cable?
Send us your length, and project details. We come back with pricing and lead times.