Indoor Fiber Optic Cable
Distribution Cable
Indoor Optical Fiber Distribution Cable
Indoor tight-buffered cable for building risers and horizontal runs.

Overview
What this cable is built for.
Up to 24 fibers, the cable bundles tight-buffered fibers with high-modulus aramid yarn under a PVC or LSZH jacket.
Above 24 fibers, branched versions strand single-tube distribution units around a GFRP or KFRP central strength member.
Key features
- Tight-buffered fibers
- Aramid yarn strength member
- PVC or LSZH jacket
- Branched versions above 24 fibers
Applications
- Indoor integrated wiring
- Building backbone
Specifications
Technical specifications.
| 2 | Strength member high modulus aramid yarn; Cable diameter 4.5±0.18 ± 0.008 in (0.2 mm); Cable weight 13 lb / kft (19.2 kg / km); Minimum bending radius static 1.77 in (45 mm); Minimum bending radius dynamic 3.54 in (90 mm); Tensile load Short term 90 lbf (400 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 2 | Strength member high modulus aramid yarn; Cable diameter 4.5±0.18 ± 0.008 in (0.2 mm); Cable weight 13 lb / kft (19.2 kg / km); Minimum bending radius static 1.77 in (45 mm); Minimum bending radius dynamic 3.54 in (90 mm); Tensile load Short term 90 lbf (400 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 4 | Strength member high modulus aramid yarn; Cable diameter 5.0±0.20 ± 0.008 in (0.2 mm); Cable weight 14 lb / kft (20.5 kg / km); Minimum bending radius static 1.97 in (50 mm); Minimum bending radius dynamic 3.94 in (100 mm); Tensile load Short term 90 lbf (400 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 4 | Strength member high modulus aramid yarn; Cable diameter 5.0±0.20 ± 0.008 in (0.2 mm); Cable weight 14 lb / kft (20.5 kg / km); Minimum bending radius static 1.97 in (50 mm); Minimum bending radius dynamic 3.94 in (100 mm); Tensile load Short term 90 lbf (400 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 6 | Strength member high modulus aramid yarn; Cable diameter 5.5±0.22 ± 0.008 in (0.2 mm); Cable weight 19 lb / kft (28.3 kg / km); Minimum bending radius static 2.17 in (55 mm); Minimum bending radius dynamic 4.33 in (110 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 6 | Strength member high modulus aramid yarn; Cable diameter 5.5±0.22 ± 0.008 in (0.2 mm); Cable weight 19 lb / kft (28.3 kg / km); Minimum bending radius static 2.17 in (55 mm); Minimum bending radius dynamic 4.33 in (110 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 8 | Strength member high modulus aramid yarn; Cable diameter 6.0±0.24 ± 0.008 in (0.2 mm); Cable weight 22 lb / kft (32.93 kg / km); Minimum bending radius static 2.36 in (60 mm); Minimum bending radius dynamic 4.72 in (120 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 8 | Strength member high modulus aramid yarn; Cable diameter 6.0±0.24 ± 0.008 in (0.2 mm); Cable weight 22 lb / kft (32.93 kg / km); Minimum bending radius static 2.36 in (60 mm); Minimum bending radius dynamic 4.72 in (120 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 12 | Strength member high modulus aramid yarn; Cable diameter 6.5±0.26 ± 0.008 in (0.2 mm); Cable weight 25 lb / kft (36.5 kg / km); Minimum bending radius static 2.56 in (65 mm); Minimum bending radius dynamic 5.12 in (130 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 12 | Strength member high modulus aramid yarn; Cable diameter 6.5±0.26 ± 0.008 in (0.2 mm); Cable weight 25 lb / kft (36.5 kg / km); Minimum bending radius static 2.56 in (65 mm); Minimum bending radius dynamic 5.12 in (130 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 16 | Strength member high modulus aramid yarn; Cable diameter 7.0±0.28 ± 0.008 in (0.2 mm); Cable weight 30 lb / kft (45.2 kg / km); Minimum bending radius static 2.76 in (70 mm); Minimum bending radius dynamic 5.51 in (140 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 16 | Strength member high modulus aramid yarn; Cable diameter 7.0±0.28 ± 0.008 in (0.2 mm); Cable weight 30 lb / kft (45.2 kg / km); Minimum bending radius static 2.76 in (70 mm); Minimum bending radius dynamic 5.51 in (140 mm); Tensile load Short term 148 lbf (660 N); Tensile load Long term 45 lbf (200 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 24 | Strength member high modulus aramid yarn; Cable diameter 8.5±0.33 ± 0.008 in (0.2 mm); Cable weight 45 lb / kft (67.2 kg / km); Minimum bending radius static 3.35 in (85 mm); Minimum bending radius dynamic 6.69 in (170 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 24 | Strength member high modulus aramid yarn; Cable diameter 8.5±0.33 ± 0.008 in (0.2 mm); Cable weight 45 lb / kft (67.2 kg / km); Minimum bending radius static 3.35 in (85 mm); Minimum bending radius dynamic 6.69 in (170 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 11 lbf / in (200 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 36 | Strength member high modulus aramid yarn; Cable diameter 14.2±0.56 ± 0.02 in (0.5 mm); Cable weight 60 lb / kft (89.8 kg / km); Minimum bending radius static 5.59 in (142 mm); Minimum bending radius dynamic 11.18 in (284 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 36 | Strength member high modulus aramid yarn; Cable diameter 14.2±0.56 ± 0.02 in (0.5 mm); Cable weight 60 lb / kft (89.8 kg / km); Minimum bending radius static 5.59 in (142 mm); Minimum bending radius dynamic 11.18 in (284 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 48 | Strength member high modulus aramid yarn; Cable diameter 16.2±0.64 ± 0.02 in (0.5 mm); Cable weight 72 lb / kft (106.9 kg / km); Minimum bending radius static 6.38 in (162 mm); Minimum bending radius dynamic 12.76 in (324 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 48 | Strength member high modulus aramid yarn; Cable diameter 16.2±0.64 ± 0.02 in (0.5 mm); Cable weight 72 lb / kft (106.9 kg / km); Minimum bending radius static 6.38 in (162 mm); Minimum bending radius dynamic 12.76 in (324 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 72 | Strength member high modulus aramid yarn; Cable diameter 19.5±0.77 ± 0.02 in (0.5 mm); Cable weight 391 lb / kft (581.3 kg / km); Minimum bending radius static 7.68 in (195 mm); Minimum bending radius dynamic 15.35 in (390 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 72 | Strength member high modulus aramid yarn; Cable diameter 19.5±0.77 ± 0.02 in (0.5 mm); Cable weight 391 lb / kft (581.3 kg / km); Minimum bending radius static 7.68 in (195 mm); Minimum bending radius dynamic 15.35 in (390 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 96 | Strength member high modulus aramid yarn; Cable diameter 22.8±0.90 ± 0.03 in (0.8 mm); Cable weight 536 lb / kft (797.8 kg / km); Minimum bending radius static 8.98 in (228 mm); Minimum bending radius dynamic 17.95 in (456 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 96 | Strength member high modulus aramid yarn; Cable diameter 22.8±0.90 ± 0.03 in (0.8 mm); Cable weight 536 lb / kft (797.8 kg / km); Minimum bending radius static 8.98 in (228 mm); Minimum bending radius dynamic 17.95 in (456 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 144 | Strength member high modulus aramid yarn; Cable diameter 26.4±1.04 ± 0.03 in (0.8 mm); Cable weight 489 lb / kft (728.4 kg / km); Minimum bending radius static 10.39 in (264 mm); Minimum bending radius dynamic 20.79 in (528 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
| 144 | Strength member high modulus aramid yarn; Cable diameter 26.4±1.04 ± 0.03 in (0.8 mm); Cable weight 489 lb / kft (728.4 kg / km); Minimum bending radius static 10.39 in (264 mm); Minimum bending radius dynamic 20.79 in (528 mm); Tensile load Short term 297 lbf (1320 N); Tensile load Long term 90 lbf (400 N); Crush load Short term 57 lbf / in (1000 N / 100 mm); Crush load Long term 17 lbf / in (300 N / 100 mm); Temperature range -4 °F to +140 °F (-20 °C to +60 °C) |
Ready to order Distribution Cable?
Send us your length, and project details. We come back with pricing and lead times.